How PV works

Orientation, Pitch and Shading

For optimal performance of the photovoltaic array it should face between south-east and south-west, at an elevation of about 30-40°. However, in the UK even flat roofs receive 90% of the energy of an optimum pitched system.

It is important to ensure that your PV system will not be shaded during the day. Avoid placing the array where there will be significant shading from surrounding buildings or trees, since this will decrease the output from the system.

Although generally installed on a roof, PV systems can be installed on any south facing elevation it can also be used for solar shading or as a rain screen on a building wall – this is particularly suitable for prestige buildings.

AC outputs in kWh/KWp

Effect of Orientation and Pitch on Array Performance (% of ideal).

 

 

 

 

Vert 80 70 60 50 40 30 20 10 Horiz
East 58 65 70 76 80 84 86 88 90 90
SE 69 77 84 89 93 96 96 96 94 90
South 71 80 87 93 97 100 100 98 96 90
SW 67 75 82 87 92 95 96 96 94 90
West 56 63 69 74 78 82 86 87 89 90

Solar Irradiance

Average annual solar radiation (kWh/m²/day)
for Great Britain and Ireland.

Planning

The majority of buildings will not require planning permission for the installation of PV systems. If however the building is in a conservation area or is a listed building you may need to apply for full planning permission. Kingspan recommend checking with your local council to ascertain the planning requirement for your specific project / building.